April 1997
Maintenance Object Repair Procedures
Page 10-1018
PDMODULE, TDMODULE (Data Module)
10
Data Module Internal Loop Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the
building wiring, through an internal looparound path in the data module under
test, and back to the PBX.
building wiring, through an internal looparound path in the data module under
test, and back to the PBX.
shows the hardware configuration used
for this test.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS
Data Module Audits passed. This digital port circuit
pack is functioning properly.
pack is functioning properly.
1. If complaints still exist, investigate by using other
port tests, and by examining the data module
options, wiring, and connections.
options, wiring, and connections.
Table 10-291.
TEST #17 Data Module Audits Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page