Maintenance Object Repair Procedures 
Page 10-1018
PDMODULE, TDMODULE (Data Module) 
10
Data Module Internal Loop Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the 
building wiring, through an internal looparound path in the data module under 
test, and back to the PBX. 
 shows the hardware configuration used 
for this test.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS
Data Module Audits passed. This digital port circuit 
pack is functioning properly.
1. If complaints still exist, investigate by using other 
port tests, and by examining the data module 
options, wiring, and connections.
Table 10-291.
TEST #17 Data Module Audits Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation