Maintenance Object Repair Procedures 
Page 10-1357
TAPE (Tape Unit) [G3iV1.1-286] 
10
Status Request Test (#69)
This test requests the Maintenance/Tape Processor (MTP) firmware on the TN773 
Processor circuit pack for the current Tape Unit status and displays the results.
Tape DMA Latch Test (#230)
Also known as the 
Tape Interface Test
, this test checks the shared RAM on the 
TN770 Memory circuit pack. The test also checks the communication paths on 
the TN773 Processor circuit pack.
Table 10-411.
TEST #69 Status Request Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance 
documentation for a description of these error codes.
9000’s
ABORT
Refer to Table A in 
 and follow the recommended repair strategy for 
specific Aux Data.
Any 
Others
FAIL
Refer to Table B in 
 and follow the recommended repair strategy for 
specific Aux Data.
PASS
This test verifies the basic communication between the 
Processor and the Tape Drive circuit pack.
Continued on next page
Table 10-412.
TEST #230 DMA Latch Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance 
documentation for a description of these error codes.
23001
ABORT
Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page