Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-17
busyout link 
8
released. Also the link will be marked out of service and inaccessible to call 
processing for use. Warning alarms are generated (error type 18) on each 
maintenance object busied out, so that INADS can access the state of the 
objects. The release link command will return the objects to operation.
Defaults
None.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "busyout link," the following 
message will be displayed:
 Enter 1 character link number
Error Messages
If the link identifier is not valid, the following error message is displayed:
 Link out of range, please press 
HELP
If the link is not administered, the following error message is displayed:
 Link not administered or not enabled
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message is displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message is displayed:
 All maintenance resources busy; try again later
link-id
The link-id is a number associated with each link between 1-8. 
Link 1 through 4 reside on Processor Interface circuit pack 
"1a1" or "1b1" and 5 through 8 reside on Processor Interface 
circuit pack "1a2" or "1b2."