Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-15
busyout journal-printer
8
Parameters
Help Messages
If the system technician presses
HELP
after entering "busyout journal-printer," the
following object command word choices will be displayed:
pms-log wakeup-log
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
following message will be displayed:
All maintenance resources busy; try again later
Error Message
Link not administered not enabled
Output
For the following output example, assume that the command that was entered is
"busyout journal-printer wakeup-log."
"busyout journal-printer wakeup-log."
pms-log
This will busyout the link to the pms printer. In the output the port name
for the pms link is 1.
for the pms link is 1.
wakeup-log
This will busyout the link to the wakeup logging facility. In the output the
port name for this object is 0.
port name for this object is 0.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out. In this case, the physical object
port address will be a 0 for wakeup log and a 1 for the pms log.
object that is being busied out. In this case, the physical object
port address will be a 0 for wakeup log and a 1 for the pms log.
Maintenance Name
The type of maintenance object that is being busied out.
Alt. Name
Not applicable.
Result
An indicator as to whether the object was successfully busied
out.
out.
Error Code
A numerical description of why the command failed.