DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1544
UDS1-BD (UDS1 Interface Circuit Pack) 
10
NPE Connection Audit Test (#50)
The system sends a message to the on-board microprocessor to update the 
network connectivity translation for the SCOTCH-NPE chip on the circuit pack.
Table 10-456.
TEST #50 NPE Connection Audit Test 
Error 
Code
Test 
Result
Description/ Recommendation
None 
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
1019
ABORT
The test aborted because a test was already running on 
the port.
1. Retry the command at 1 minute intervals for a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort/fail, escalate the 
problem.
PASS
The circuit pack’s SCOTCH-NPE chip have been 
updated with its translation.
Continued on next page