Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1595
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information specified by 
System Administration to the UDS1 Interface circuit pack. Translation includes 
the following data administered for a UDS1 Interface circuit pack (see output of 
display ds1 PCSS
 command): DS1 Link Length between two DS1 endpoints, 
Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling 
Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
In G3V3, if a TN464F or later UDS1 circuit pack is combined with an AT&T 120A1 
CSU Module to form and Integrated CSU Module, this test will also send the 
administration for this Integrated CSU to the circuit pack to assure the board’s 
translations are correct. The administration of the CSU Module is done using the 
DS1 circuit pack administration form. Translation for the CSU Module includes 
the following data: Transmit LBO, Receive ALBO, Supply CPE Loopback Jack 
Power?, etc.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-467.
TEST #145 Misframe Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page