Maintenance Object Repair Procedures 
Page 10-1596
UDS1-BD (UDS1 Interface Circuit Pack) 
10
DS1 Board Loopback Test (#1209)
This test is destructive.
Table 10-468.
TEST #146 Translation Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
 
ABORT
Internal System Error 
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
 
FAIL
Internal system software error.
1. Enter the 
display ds1 PCSS
 command to verify the 
UDS1 Interface circuit pack translation.
2. If the test continues to fail, escalate the problem.
 
PASS
Translation data has been downloaded to the UDS1 
Interface circuit pack successfully.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Continued on next page