Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-168
format card-mem 
8
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
 All maintenance resources busy
Output
If the enable test-number command is successful, the following message will be 
displayed on the SAT:
 Command successfully completed
If the enable test-number command is unsuccessful, the following message will 
be displayed on the SAT:
 Error encountered, cannot complete request
Feature Interactions
The display disabled-tests command gives a list of all disabled tests.
format card-mem
This command formats the active processor Flash Read-Only Memory.
Synopsis
format card-mem [translation] [announcements] [coredump] [firmware]
Permissions
The following default logins may execute this command: browse, system 
technician, cust, inads, init.
Examples
format card-mem translation
format card-mem announcements
format card-mem coredump
format card-mem firmware