set expansion-link 
8
set expansion-link
This command sets the Expansion-Interface Link between the PPN and an EPN 
or between two EPNs to a specific Interface Link circuit pack between PPN and 
EPN.
Synopsis
set expansion-link link-identifier
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
set expansion-link 02a01
set expansion-link 3a02
Description
This command sets the Expansion-Interface Link between the PPN and an EPN 
or between two EPNs to a specific Interface Link circuit pack between PPN and 
EPN.
Note: This command can corrupt any active data links between the PPN and an 
EPN or between two EPNs.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses 
HELP 
after entering "set expansion-interface," the 
following message will be displayed:
Enter board location: 
[cabinet(1-3)];carrier(A-E);slot(0-20)
link-identifier
The circuit pack address of the designated Standby Expansion 
Interface circuit pack (identified as 1A01, 1A02, 1B01, 1B02, 2A01, 
2A02, 2B03, 3A01, 3A02, 3AB02 or 3B03).