Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-470
status link 
8
Error Messages
If the specified link number is invalid, the following message is displayed:
Link out of range, please press HELP
If the specified link number is not administered, the following message is 
displayed:
Link not administered
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message is displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message is displayed:
All maintenance resources busy; try again later
DEFINITIONS
Link
A synchronous connection between the Definity system and an 
adjunct or another switch. The link consists of three protocol 
levels. The entire link is identified by a link number which is 
specified on the "change communications-interface links" form.
Level 1
Physical connection of a port on a Processor Interface board to 
hardware which serves the same purpose on the adjunct or switch 
(for example, a PI board or an SCP board on Audix). There can be 
several components between these two endpoints (modems, DS1 
facilities, cables, and so forth).