DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-537
test alarms 
8
Parameters
auto-page
This option provides the ability to continue testing and displaying test 
results, by providing a new screen every time the SAT screen is filled 
with test results. The screen does not scroll to accommodate new 
results; instead a new screen is provided after the current screen fills 
up.
If the auto-page option is not specified, the SAT screen will not be 
refreshed once it is filled with test results and testing will stop until the 
user enters the "PAGE" key to continue or the "CANCEL" key to halt the 
testing.
failures
This requests that only the failures be displayed on the screen. All 
passes will not be displayed on the output screen. Hardware failures as 
well as aborts, conflicts and EPN-down failures will be displayed.
step
This option will allow the user to step to the next or previous alarm and 
not have the current alarm tested. When this option is specified, the 
user is presented with the alarm information and prompted for a 
keypress. The user may enter CANCEL to abort the command, ENTER 
to test the currently displayed alarm, NEXT ALARM (function key) to 
move to the next alarm, PREV ALARM (function key) to move to the 
previous alarm without testing the currently displayed alarm. If this 
option is given, then the NEXT ALARM (function key) or PREV ALARM 
(function key) may be pressed at any time during the command (even 
during test results). If the NEXT ALARM or PREV ALARM is pressed 
during a test, the test is aborted, testing of the current alarm stops, and 
the next alarm or previous alarm is displayed. If the first alarms is 
displayed, and the PREV ALARM is pressed, then the last alarm is 
displayed. Also, if the last alarm is currently displayed, and the NEXT 
ALARM is requested, then the first alarm will be shown.
NOTE:
When this option is given the only way to terminate this command 
is to press CANCEL
.
short
This will cause the command to execute a series of nondestructive 
diagnostic tests.