Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-539
test alarms 
8
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
QUERY FORM INPUT
After entering the command "test alarms", the system technician will be 
presented with an options form for alarm selection.
Alarm Types
The type of alarm to be tested is specified by placing a ’y’ or ’n’ in the 
alarm type fields. The technician can choose a combination of active 
alarms: major, minor, and/or warning.
Interval
Test alarms for records for the last hour (h), last day (d), last week (w) 
or all (a). The default is all.
 
 test alarms repeat 1
             HARDWARE TEST ALARM QUERY
     The following options control which alarms will be tested.
     ALARM TYPES
           Major? y_     Minor? y_    Warning? y_
         REPORT PERIOD
          Interval: m_  From: __/__/__:__  To: __/__/__:__
     EQUIPMENT TYPE ( Choose only one, if any, of the following )
                            Cabinet: __
                       Port Network: __
                       Board Number: ____
                               Port: ______
                           Category: ________
                          Extension: _____
             Trunk ( group/member ): __/__