Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-616
test memory 
8
Feature Interactions
The long test on EPN maintenance circuit packs will cause the EPNSAT link to be 
dropped. The reset test is the last test and drops this link.
test memory
This command will test memory circuit packs.
Synopsis
test memory location 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, init, nms.
Examples
test memory
test memory a
test memory a schedule
test memory 1a2
test memory b1 sh
test memory b l r 25
test memory a l c
 
 test maintenance 2
                               TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
   02A     MAINT                       106      PASS
   02A     MAINT                       229      PASS
   02A     MAINT                       303      PASS
   02A     MAINT                       337      PASS
 Command Successfully Completed