Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-645
test pri-endpoint
8
Error Messages
If the format for the extension is incorrect, the following error message will be
displayed:
displayed:
Extension invalid
If the EPN on which the PRI endpoint resides is not accessible, the following
message will be displayed:
message will be displayed:
EPN is not available
If the extension is not administered, the following message will be displayed:
Extension not assigned
If the object associated with the specified extension is not a PRI endpoint, the
following message will be displayed:
following message will be displayed:
Extension assigned to object other than pri-endpoint
If the board that contains the PRI endpoint is not inserted in the system, the
following message will be displayed:
following message will be displayed:
Board not inserted
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a port-by-port and test-by-test basis with one
line of data displayed for each test result.
line of data displayed for each test result.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
object that is being tested.
Maintenance Name
The type of maintenance object that is being tested. The name for
PRI endpoint port is "PE-BCHL".
PRI endpoint port is "PE-BCHL".
Alt. Name
The alternate way of identifying the maintenance object. This field
contains the specified extension number of the PRI endpoint.
contains the specified extension number of the PRI endpoint.