Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Packet Bus Fault Isolation and Correction 
Page 9-19
Packet Bus Fault Isolation Flowchart 
9
8. If the data matches the previously recorded data, a Packet Bus problem 
exists. The original TN771 Maintenance/Test circuit pack is not defective, 
and it does not need to be returned to the factory. Replace the original 
TN771, then correct the Packet Bus problem by using the procedures in 
the sections that follow.
9. If the data does 
not
 match the previously recorded data, 
the original 
TN771 Maintenance/Test circuit pack is defective
. If there are still 
indications of Packet Bus problems, correct them by using the procedures 
in the sections that follow.
Packet Bus Fault Isolation Flowchart
The flowchart in this section presents the steps to be taken for isolating and 
resolving Packet Bus problems. The order in which the maintenance objects 
should be examined can be determined by assessing how wide-spread the 
failure is. For example, since all ISDN-BRI devices communicate with the TN778 
Packet Control circuit pack, this MO should be examined early in the sequence. 
On the other hand, a failure of a TN570 circuit pack in an EPN may cause 
ISDN-BRI failure in an EPN, but it could not be the cause of a failure in the PPN.
Whenever the flowchart refers to the Maintenance documentation for a specific 
MO, keep in mind that the repair procedure for that MO may in turn refer to 
another MO’s repair procedure. The flowchart tries to coordinate these 
procedures so that a logical flow is maintained if the Packet Bus problems are 
not resolved via the first set of repair procedures. However, a Packet Bus failure 
can lead to a somewhat haphazard referencing of various MO procedures that 
may result in your implementing steps that either have already been completed 
or are not necessary. If this occurs, return to the flowchart at the step that follows 
the reference to 
, and then 
continue.
NOTE:
The following 
status
 commands can also help diagnose Packet Bus 
problems:
status system
status packet-control
status bri-port
status station
status data-module
For a description of these commands, refer to the "Status Commands" 
section in 
. The commands provide information about the service state of 
various Packet maintenance objects. This information can be useful for 
remote maintenance, inasmuch it can explain the impact of the failure(s) 
on the system.