Baldor Baldor Manual Do Utilizador

Página de 70
Section 1
General Information
4-14 Parameter Index
MN850
Title
P#
Parameter
Description
Parameters
100
Flag1 O/P Destination Mask
The bit mask for destination flag parameter.
Continued
101
Flag2 I/P Source Address
Address of source flag parameter. 
(Parameter 102 is the mask for P101.)
102
Flag2 I/P Source Mask
The bit mask for source flag parameter.
103
Flag2 O/P Destination Address
Address of destination flag parameter. 
(Parameter 104 is the mask for P103.)
104
Flag2 O/P Destination Mask
The bit mask for destination flag parameter.
105
Loop Input
The parameter number used as the source for control loop setpoint.
106
Loop Feedback
The parameter number used as the source for control loop feedback.
107
Error Gain
Multiplier for the control loop error signal.
108
Error Divisor
Divisor for the control loop error signal.
109
Max Slope
The maximum allowed single error in open loop.
110
Guard Gap
The minimum allowed firing delay in both open loop and phase
control modes. This allows for jitter and power factor of the load.
Parameters
111
User Parameter
This parameter may be set by the user by the serial link.
Continued
112
Status 4
Definition (Preset Value, all = 0)
Bit0= 
The unit is using 60Hz parameters
Bit1=
The phase rotation detected at start (RYB Sequence)
Bit2=
Indicates current is greater than shearpin level
Bit3=
Indicates current is less than under current level
Bit4=
Thermistor is overtemperature or I/P's are open circuit
Bit5=
Current limit has timed out
Bit6=
Overload has passed trip level
Bit7=
Heatsink temperature is greater than max allowed
113
Drive Type
Unused
114
Baud Rate
Unused
115
Selected App
Value selected from application table. Not implemented on some
versions of software.
116
5MC Inhibit Time (restart not allowed)
Number of minutes after stop that restart is not allowed. (Protects
SCR’s for large loads.)
117
Command Source
Unused
118
Action On Bus Error
Unused
119
Preset Parameter Number to Display
Unused
120
Status 5
Definition (Preset Value)
Bit0= 
Thermal Switch 2 Over temp . Prevents re-start if set. (0, Off)
121
User Flags 4
Definition (Preset Value)
Bit0= 
Unused
Bit1=
Allow for quicker comms response (0, Off)
Bit2=
enable Soft stop smoothing for pumps (0, Off)
122
Soft–Start Smoothing
Sets the amount of soft–start smoothing. This parameter helps
stabilize jitter caused by unstable loads.
123
Reserved for future use.
Unused
124
Reserved for future use.
Unused
125
Reserved for future use.
Unused