Program example for trip information reading 
Example 8 shows 
a ladder logic to 
read the trip information of station 1 inverter to D1. 
Trip history No. 1, No. 2 reading code number: 74H (hexadecimal) 
The reply code at the time of instruction code execution is set to D2. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
For example of trip information 
Read dara: 2D0EH 
 b15 
b8 b7 
b0 
0
1
0
1
0
0
0
0
1
1
1
 
 (2DH) 
(0EH) 
Past trip code 
Current
 
trip code 
e-13
(
Error code
: 2DH) 
ol2
(
Error code
: 0EH) 
" Over speed fault " 
" Motor overload " 
 
Refer to 5.5.9 for detail.          }
 
 
 
X0 
X0F X1 
( M0) 
Check the ready of the Station 1 
SW80.0 
M0 
X20 
[ PLS  M300] 
M300 
[ SET  M301] 
M301 
X100F 
[ MOV  H74  W102]
[ SET  Y100F] 
[ RST  M301] 
[ SET  M302] 
M302 
X100F 
[ MOV    W2    D1]
[ RST    Y100F] 
[ RST    M302] 
[ END] 
[ MOV    W3    D2]
Write trip history No.1, No.2 read
code (H74) to RWw2.
 
Turn on the instruction code execution 
request (RY0F) 
 
Read alarm data (RWr3) and reply code 
(RWr2) to D1 and D2 when the   
instruction code execution completion   
flag (RX0F) turns on. 
 
Turn off the instruction code execution 
request (RY0F) 
 