Avaya Comcode 700220627 Manual Do Utilizador

Página de 74
Upgrading an Enterprise 3000 to CMS R3V9
58 CentreVu CMS R3V9 Sun Enterprise 3000 Computer CVUE Instructions
Updating the switch setup
In many cases, the switch is upgraded to a new release when the CMS is upgraded with 
CVUE. In addition, the links from the switch to the CMS may need conversion from X.25 to 
TCP/IP. If either of these happen, you must do the following:
Readminister each ACD on the CMS using the 
swsetup
 option of the 
cmssvc
 
command. CMS must be turned off to administer the ACDs. Remember to turn CMS on 
after setting up the ACDs. Readministering the ACDs includes converting the link from 
X.25 to TCP/IP, if appropriate. For more information about converting links, see 
CentreVu CMS Switch Connections, Administration, and Troubleshooting, 585-215-876.
Note:
While you have CMS turned off, you can save time by 
 at the same time.
Readminister the CMS version on the switch using the Customer Options form. This 
change requires superuser permissions. Contact your technical support organization or 
your COE for assistance.
Check the switch links on the CMS main window and verify that the switch links are up.
If the conversion from X.25 to TCP/IP involves adding another network card to the CMS 
computer, this must be done after the CVUE upgrade is completed.
Continue with 
Setting the Informix configuration parameters
The Informix Dynamic Server (IDS) parameters for CMS must be adjusted to optimize 
system performance. Adjusting these parameters allows the system to fully utilize 
additional processors and memory.
Note:
During this procedure, both CMS and IDS must be turned off.
To adjust the IDS parameters, see the section 
Setting the Informix configuration 
parameters for CMS in the chapter Installing CMS and Supporting Software of CentreVu 
CMS R3V9 Software Installation, Maintenance, and Troubleshooting, 585-215 956.
Continue with 
.