Cisco Systems 57712 Manual Do Utilizador

Página de 288
PSU2_STATUS
Normal
present
Server /sensor #
show psu-redundancy
Name
Reading
Sensor Status
-------------------- ---------- --------------------
PSU_REDUNDANCY
full
Normal
Server /sensor #
Viewing Fan Sensors
Procedure
Purpose
Command or Action
Enters sensor command mode.
Server# scope sensor
Step 1
Displays fan sensor statistics for the server.
Server /sensor # show fan [detail]
Step 2
This example displays fan sensor statistics:
Server#
scope sensor
Server /sensor #
show fan
Name
Sensor Status
Reading
Units
Min. Warning
Max. Warning
Min. Failure
Max. Failure
-------------------- -------------- ---------- ---------- --------------- ---------------
--------------- ---------------
W793_FAN2_TACH1
Normal
2400
RPM
N/A
N/A
800
N/A
W793_FAN2_TACH2
Normal
2400
RPM
N/A
N/A
800
N/A
W793_FAN3_TACH1
Normal
2300
RPM
N/A
N/A
800
N/A
W793_FAN3_TACH2
Normal
2300
RPM
N/A
N/A
800
N/A
W793_FAN4_TACH1
Normal
2400
RPM
N/A
N/A
800
N/A
W793_FAN4_TACH2
Normal
1600
RPM
N/A
N/A
800
N/A
Server /sensor #
Viewing Temperature Sensors
Procedure
Purpose
Command or Action
Enters sensor command mode.
Server# scope sensor
Step 1
Displays temperature sensor statistics for the
server.
Server /sensor # show temperature [detail]
Step 2
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
50
OL-28893-01  
Viewing Server Sensors