Cisco Systems 57712 Manual Do Utilizador

Página de 288
1.744
1.852
Server /sensor #
Viewing Current Sensors
Procedure
Purpose
Command or Action
Enters sensor command mode.
Server# scope sensor
Step 1
Displays current sensor statistics for the server.
Server /sensor # show current [detail]
Step 2
This example displays current sensor statistics:
Server#
scope sensor
Server /sensor #
show current
Name
Sensor Status
Reading
Units
Min. Warning Max. Warning
Min. Failure Max. Failure
------------------------- -------------- ---------- ---------- ------------ ------------
------------ ------------
VR_P2_IMON
Normal
16.00
AMP
N/A
147.20
N/A
164.80
VR_P1_IMON
Normal
27.20
AMP
N/A
147.20
N/A
164.80
Server /sensor #
Viewing Storage Sensors
Procedure
Purpose
Command or Action
Enters chassis command mode.
Server# scope chassis
Step 1
Displays storage sensor information.
Server /chassis # show hdd [detail]
Step 2
The displayed fields are described in the following table:
Description
Name
The name of the storage device.
Name column
A brief description of the storage device status.
Status column
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
52
OL-28893-01  
Viewing Server Sensors