Fractional T1 Configuration Using PPP
WPIM-RT1 User’s Guide
3-15
The line configuration information shown in 
 must be supplied 
by the service provider.
3.4.1
T1 Physical Configuration
Begin the WPIM-RT1 physical configuration by accessing the WAN 
Physical Configuration
 screen through Local Management (
Proceed with the following steps:
1.
Use the arrow keys to highlight the [WPIM X] field at the bottom of 
the screen. Press the SPACE bar to select the number of the WPIM 
being configured, then press ENTER.
2.
Use the arrow keys to highlight MgrType. Select PPP.
3.
Use the arrow keys to highlight Timeslot View. Press the SPACE bar 
to select New, then press ENTER. The cursor moves to Timeslot #1 of 
the Timeslot Configuration Table.
4.
) into every 
Timeslot being used (in the example shown in 
Timeslots are used, the rest have zeros in them). Type the number, 
press ENTER, then use the arrow keys to highlight the next Timeslot 
field. Exit this field by using the arrow keys.The cursor automatically 
moves to the T1 Line Coding field.
Table 3-2
Telco Configuration Information
Configuration Information 
Required by User
Information Supplied by 
Service Provider
Line Coding
B8ZS or AMI
Frame Type
ESF or D4
Clock Source
Loop Timing or Local Timing
DS-0s (Timeslots)
Timeslots being used for each end of 
the circuit
NOTE
When changing from one protocol to another on a WPIM-RT1 
that has been operational, save NONE as the protocol before 
changing to another protocol.