Cabletron Systems WPIM-RT1 Manual Do Utilizador

Página de 50
Frame Relay Configuration
WPIM-RT1 User’s Guide
3-17
3.4.2
T1 Interface Configuration
The WAN Interface Configuration screen is accessed through the WAN 
Physical Configuration screen. Access the WAN Interface Configuration 
screen by using the arrow keys to highlight the WAN INT CONFIG 
command and press ENTER. Refer to 
following steps to configure the WAN Interface.
1.
Set the WAN connection Interface Number by typing the same 
number into the Interface Number field that was input into the 
timeslots in the WAN Physical Configuration screen, then press 
ENTER (see the Notes on
2.
Unless the user sets the Max Xmit Unit, the WPIM-RT1 automatically 
sets the Max Xmit Unit to 1526 (default) after the active protocol 
(PPP) is selected.
3.
Make any changes to the available settings as desired.
4.
Use the arrow keys to highlight the SAVE command, then press 
ENTER. The message ““SAVE DONE!” displays and Local 
Management saves the changes to memory.
The WAN configuration is complete. It takes up to 60 seconds for the 
WAN Interface to come out of standby and for communications to begin.
3.5
FRAME RELAY CONFIGURATION
This section provides step-by-step instructions for configuring the 
WPIM-RT1 to use a T1 circuit in a Frame Relay environment. This 
example assumes the setup shown in 
 using two CSX400s, each 
with a WPIM-RT1 installed. Configurations may vary depending on the 
host platform.
Figure 3-8
Frame Relay Configuration
SITE #1
Telco Cloud
24 Timeslots
24 Timeslots
SITE #2
1482_05