Chapter 3: Local Management
3-18
WPIM-RT1 User’s Guide
The line configuration information shown in 
 must be supplied 
by the service provider.
3.5.1
Frame Relay Physical Configuration
Begin the WPIM-RT1 physical configuration by accessing the WAN 
Physical Configuration
 screen through Local Management (
). 
Proceed with the following steps:
1.
Use the arrow keys to highlight the [WPIM X] field at the bottom of 
the screen. Press the SPACE bar to select the number of the WPIM to 
be configured, then press ENTER.
Use the arrow keys to highlight the MgrType field. Configure Protocol 
Manager Type as either FR PtoMP or FR PtoP. There are two settings for 
Frame Relay, Point-to-Point (FR PtoP) and Point-to-Multipoint (PtoMP). 
Frame Relay Point-to-Point has one Interface per DLCI assigned when 
DLCIs are created by the Service Provider. In Frame Relay 
Point-to-Multipoint, there is one interface to multiple DLCIs, and the 
DLCIs are dynamically learned. Backup can only be run on FR PtoP, not 
FR PtoMP. 
2.
Use the arrow keys to highlight Timeslot View. Press the SPACE bar 
to select New, then press ENTER. The cursor moves to the first 
timeslot available in the Timeslot Configuration Table.
Table 3-3
Telco Configuration Information
Configuration Information 
Required by Customer
Information Supplied by 
Service Provider
Line Coding
B8ZS or AMI
Frame Type
ESF or D4
Clock Source
Loop Timing or Local Timing
DS-0s (Timeslots)
Timeslots being used for each end of 
the circuit
NOTE
When changing from one protocol to another on a WPIM-RT1 
that has been operational, save NONE as the protocol before 
changing to another protocol.