Campbell Hausfeld SDM-CD16AC Manual Do Utilizador

Página de 22
SDM-CD16AC 16 Channel AC/DC Controller 
9:  Else (P94) 
   
Else, If the heater is off, 
 
10:  Z=F (P30) 
   
 
 1:  0 
 F 
 
Enter a "0" into heater 
  2:  0 
  Exponent of 10  
control location 
  3:  10-- 
  Z Loc :  
 
11: End (P95) 
   
End Then Do/Else/End 
 
END HEATER CONTROL LOGIC 
 
START COOLER CONTROL LOGIC 
 
12:  If X<=>F (P89) 
If "Cooler" on 
 1:  1-- 
 X 
Loc 
 
threshold is 
 2:  3 
 >= 
 
exceeded 
 3:  27.5 
 F 
 
 4:  30 
 Then 
Do 
 
Then 
 
13:  Z=F (P30) 
   
Put a "1" into cooler 
 1:  1 
 F 
 
Control Location 
  2:  0 
  Exponent of 10  
  3:  15-- 
  Z Loc :  
 
14:  End (P95) 
   
End Then Do/End 
 
15:  If X<=>F (P89) 
If cooler is on 
 1:  15-- 
 X 
Loc 
 
(Cooler control 
 2:  2 
 <> 
 
Location <>0) 
 3:  0 
 F 
 
 4:  30 
 Then 
Do 
 
Then 
 
16:  If X<=>F (P89) 
Check lower threshold to 
 1:  1-- 
 X 
Loc 
 
see if cooler should be 
 2:  4 
 < 
 
turned off 
 3:  24.5 
 F 
 
 4:  30 
 Then 
Do 
 
 
17:  Z=F (P30) 
   
If cooler should be turned 
 1:  0 
 F 
 
off, put a "0" into cooler 
  2:  0 
  Exponent of 10  
control location 
  3:  15-- 
  Z Loc :  
 
18:  End (P95) 
   
End Then Do/End 
 
19:  Else (P94) 
   
Else if cooler is off 
 
20:  Z=F (P30) 
   
 
 1:  0 
 F 
 
Put a "0" into cooler 
  2:  0 
  Exponent of 10  
control location 
  0:  15-- 
  Z Loc :  
 
13