Campbell Hausfeld SDM-CVO4 Manual Do Utilizador

Página de 30
Instruction Manual 
 7:  -1666.67 B3 
 8:  10 
A4 
 9:  -5000 
B4 
 
; Now update the SDM-CVO4 with the information 
; for the four channels 
 
11:  SDM-AO4 (P103) 
 1:  4 
Reps 
 2:  30 
SDM 
Address 
  3:  5 
Loc [ ScldOut_1 ] 
 
6.2.2  Restricted Range Current Output Modes (4-20 mA) 
When driving a system that requires a restricted current range then the full-scale 
range is reduced accordingly. In the case of 4-20 mA devices the maximum range 
is 8000 units and the minimum value should be scaled to  
-3000 and prevented from going below this level. 
The following partial program could be used in place of the last two instructions 
in the example above. 
; Then apply the scaling with one instruction P53 
; The readings are scaled -3000 to +5000, i.e. to 
; cover the range which would equate to 
; 4-20 mA in current mode. 
 
; Windspeed to cover the range 0-100 m/s 
; Wind direction to cover 0-360 degrees 
; Temperature -25 to +50 degrees C 
; Radiation 0 - 1000  m^2/s 
 
10:  Scaling Array (A*Loc+B) (P53) 
  1:  5 
Start Loc [ ScldOut_1 ] 
  2:  80 
A1 ; WS multiplier 
  3:  -3000 
B1 ; WS Offset 
 4:  22.2222  A2 
 5:  -3000 
B2 
 6:  106.667  A3 
 7:  -333.32  B3 
 8:  8 
A4 
 9:  -3000 
B4 
 
; Now limit the lowest scaled value to -3000 (4 mA) 
; As we have four 4-20 mA current outputs, a loop 
; construct is the easiest way to do this. 
 
11:  Beginning of Loop (P87) 
 1:  0000 
Delay 
 2:  4 
Loop 
Count 
 
; If the scaled value is less the –3000 
 
 
12:  If (X<=>F) (P89) 
 
  1:  5 
-- X Loc [ ScldOut_1 ] 
  
2: 
  
3: 
-3000  F 
 
  4:  30  
Then Do 
17