SDM-CVO4 4-Channel Current/Voltage Output Module 
 
; then set the value to –3000 
 
 
13:  Z=F (P30) 
  
1: 
-3000 
 
  2:  00 
Exponent of 10 
 
  3:  5 
-- Z Loc [ ScldOut_1 ] 
 
 
14:  End (P95) 
 
15:  End (P95) 
 
; Now update the SDM-CVO4 with the information 
; for the four channels 
 
16:  SDM-AO4 (P103) 
 1:  4 
Reps 
 2:  30 
SDM 
Address 
  3:  5 
Loc [ ScldOut_1 ] 
 
6.2.3  Providing Isolated Power Supplies to Sensors 
SDM-CVO4 to 10 V to provide 
; {CR10X} 
This program example sets all the outputs of the 
isolated power supplies to four separate sensors. The program includes code to pu
the SDM-CVO4 into standby mode after the measurements are made.  
; An example program which show use of the SDM-CVO4 
; as an isolated power supply for 4 sensors requiring 
; 10 V drive and producing 0-100 mV signals. 
; This shows how to set the SDM-CVO4 into standby mode. 
 
*Table 1 Program 
  01:   
60 
Execution Interval (seconds) 
 
; S
ixed val
 5000 = 10 V output 
tore a f
ue of
; in the four scaling locations 
 
1:  Bulk Load (P65) 
 1:  5000 
 2:  5000 
 3:  5000 
 4:  5000 
 5:  0.0 
 6:  0.0 
 7:  0.0 
 8:  0.0 
  9:  1 
Loc [ Scale_1   ] 
 
; T
 t
V
puts to 10,000 mV 
ell he SDM-C O4 to set all four out
; The SDM-CVO4 address is zero in this example. 
; This will cause the SDM-CVO4 to come out of standby 
; mode. 
 
2:  SDM-AO4 (P103) 
 1:  4 
Reps 
 2:  00 
SDM 
Address 
  3:  1 
Loc [ Scale_1   ] 
18