Adtran MX412 Manual Do Utilizador

Página de 108
Menu Descriptions
MX410/MX412 System Manual
5-42 PRELIMINARY
61189500L1-1B
Test Menu
The Test menu (see 
provides options for testing the DS1 Ports. 
Figure 5-26.  Test Menu
The Test menu options are shown in 
Table 5-22.  Test Menu Options
Option
Description
Function
DS1 Ports (1-4 on MX410 and 1-12 on MX412)
1-4
#1 - #4
This option is used to invokes th
5
Reset ALL Tests
This option is used to stop all DS1 port testing and resets all DS1 
ports to Data Mode.
6
Loopback Timeout
This option is used to set the loopback timeout value. The default 
value is 120 Minutes and the possible values are as follows:
• 120  Minutes
•   90  Minutes
•   60  Minutes
•   30  Minutes
•   15  Minutes
•   10  Minutes
•   5  Minutes
•   Disabled
                                     MX410                        MM/DD/YY HH:MM
Active Alarms: CRITICAL MAJOR                           ID:                MX410
                                     Test
                                   DS1 Ports
                              1 - #1 : Pattern
                              2 - #2 : Data mode
                              3 - #3 : Data mode
                              4 - #4 : Data mode
                              5 - Reset ALL Tests
                              6 - Loopback Timeout:   120 Minutes
  Selection :                                         '?' - System Help Screen