To terminate the CT Bus, install a link clip over the 
pair of P5 pins indicated in the following figure. 
4. Choosing a Slot
The DNI2410TEPEHMPQ is a full length x1 form factor 
PCI Express board that requires 18W of power. The 
following explanation and guidelines are provided for 
configuration of the product.
Power Budgeting is a new feature, introduced in the 
PCI Express Specification, that provides a mechanism 
to enable a system to negotiate power consumption 
requirements for add-in devices.
Per PCI Express Card Electromechanical Specification 
Revision 1.0a or higher, a x1 add-in card can draw no 
more than 10W in a x1 slot unless the board’s re-
quired power is successfully negotiated and allocated 
by the system (power budgeting). However, imple-
mentation of power budgeting by a vendor's system 
is not a compliance requirement per the PCI Express 
Card Electromechanical Specification Revision 1.0a or 
higher. Therefore, some chassis may not support this 
feature. Power Budgeting jumper P10 is designed to 
ensure proper configuration of the product.
The DNI2410TEPEHMPQ must be installed in a slot 
that can be allocated 18W of power.
If Power Budgeting is not implemented by a vendor's 
system, the DNI2410TEPEHMPQ must be plugged 
into a x4 or higher slot with the P10 jumper in posi-
tion 1-2 (power budgeting ignored). This is allowed 
per PCI Express Card Electromechanical Specification 
Revision 1.0a or higher because a x4 or greater slot 
must be able to support a minimum of 25W of power.
If Power Budgeting is implemented by a vendor's sys-
tem, the DNI2410TEPEHMPQ can be plugged into a 
x1 slot but the P10 jumper must be in position pins 2-
3 (power budgeting adhered to).
WARNING! Installing the DNI2410TEPEHMPQ 
in a x1 slot with the P10 jumper in position 1-2 
will void the warranty of the 
DNI2410TEPEHMPQ.
If the DNI2410TEPEHMPQ will be connected to one or 
more other boards via a CT Bus cable, you should in-
stall the boards to minimize unused connectors on 
the CT Bus cable (in addition to ensuring that the 
power requirements are met):
Install boards in adjacent slots whenever possible.
If the DNI2410TEPEHMPQ will be connected to one 
or more PCI boards, use the PCI Express slot(s) lo-
cated closest to the PCI slots. 
CT Bus
Termination
Pins
CT Bus
Connector
5. Installing the Board
WARNING! Unplug the equipment before per-
forming the procedures described in this sec-
tion. Failure to disconnect the power before you 
open the chassis can result in personal injury. 
Ensure that the system is disconnected from its 
power source and from all telecommunications 
links, networks, or modem lines whenever the 
chassis cover is removed. Do not operate the 
system with the cover removed.
CAUTION: To avoid possible damage to the board, 
remove power from the computer before beginning 
installation. Observe proper anti-static precautions at 
all times while handling and installing the board.
To install the DNI2410TEPEHMPQ, perform the follow-
ing steps:
1. Turn off all power to the system and disconnect 
the system’s power cords. 
2. Remove the computer’s cover.
3. Choose an empty PCI Express expansion slot and 
remove that slot’s retaining screw and access 
cover plate.
4. Insert the board’s edge connector into the bus 
slot, and apply firm pressure to the top edge of 
the board until the board is fully seated in the 
edge connector. 
5. Reinstall the retaining screw.
6. Repeat Step 3 through Step 5 for any additional 
boards you are installing.
7. If applicable, connect the boards together with a 
CT Bus cable of the appropriate size (not in-
cluded). If possible, use a cable assembly that 
matches the total number of boards in your sys-
tem. If the cable has more than one unused con-
nector, install the cable so that all the unused 
connectors are at one end of the cable.
8. Replace the computer’s cover.
9. Reconnect the computer’s power cord.
PCI Slots
PCI Express
Slots
PCI Express
Board
Computer
Chassis
Remove
Cover
Plate
6. Connecting to External Equipment
Each RJ-48C jack on the DNI2410TEPEHMPQ sup-
ports two T1 or E1 digital network interfaces. A split-
ter cable set consisting of four splitter cables is pro-
vided with the board. Connect a splitter cable to each 
RJ-48C jack on the rear bracket of the 
DNI2410TEPEHMPQ. The following figure illustrates 
the pinouts of the four RJ-48C jacks on the 
DNI2410TEPEHMPQ. 
For connections to CSUs or other network termination 
equipment, the splitter cable breaks out the two T1/
E1 trunk interfaces on a single RJ-48C connector to 
the standard wire pairs of two separate RJ-48C mod-
ular connectors. On the Y-adapter end of the splitter 
cable, the connector labeled “A” is for the lower trunk 
number and the connector labeled “B” is for the 
higher trunk number supported by each cable, for ex-
ample, trunks 1&5, 2&6, 3&7, and 4&8. Each connec-
tor has the following pinouts:
7. After Installing the Board
The DNI2410TEPEHMPQ requires the use of a Dialogic 
software release that specifically supports it.
If this is the first Dialogic board you have installed in 
your system, you will need to install an appropriate 
version of the Dialogic software and to configure the 
software for the specific board(s) you are using. For 
instructions, refer to the installation and configura-
tion documentation that accompanies the release.
If you are installing the DNI2410TEPEHMPQ in a sys-
tem that already has Dialogic software installed, you 
should verify that your installed software version sup-
ports the board. If it does not support the board, you 
will need to obtain and install a Service Update that 
1
RCV_RING
4
XMIT_RING
7
Not used
2
RCV_TIP
5
XMIT_TIP
8
Not  used
3
Not  used
6
Not  used
Note:
Your CT Bus cable may 
have a different number of 
connectors (drops). 
CT Bus
Cable
Colored
Stripe
(Pin 1)
RCV_RING A
RCV_TIP A
RCV_RING B
XMIT_RING A
XMIT_TIP A
RCV_TIP B
XMIT_RING B
XMIT_TIP B
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
 Pinout for RJ–48C Jacks (4) on 
DNI2410TEPEHMPQ Bracket
Note: "A"= lower trunk number and "B"= higher trunk 
number for each connector. For example, trunks 1&5, 
2&6, 3&7, 4&8.
does support the DNI2410TEPEHMPQ before config-
uring the system for the newly installed board(s). 
Please refer to the Release Update document for your 
Dialogic software version for up-to-date information 
about support for the DNI2410TEPEHMPQ and any 
known issues relating to its use.
8. Removing the Board
Removal of the DNI2410TEPEHMPQ is essentially the 
reverse of the installation procedure, as summarized 
1. Observe anti-static precautions.
2. Disconnect the telephony cables and splitter ca-
bles.
3. Remove the computer’s power cord.
4. Remove the computer’s cover.
5. Disconnect the CT Bus cable (if applicable).
6. Remove and set aside the board’s retaining screw.
7. Remove the board and place it in static-protective 
packaging.
9. Contacting Technical Support
contact to obtain local contact information.
Dialogic also provides direct support via Dialogic
10.Returning a Product
To return a board for warranty repair or for any other 
returns, please refer to the following: 
 
All contents of this document are furnished for informational use only and are subject 
to change without notice and do not represent a commitment on the part of Dialogic 
Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the 
accuracy of the information contained in the document. However, Dialogic does not 
warrant the accuracy of this information and cannot accept responsibility for errors, 
inaccuracies or omissions that may be contained in this document. 
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC
®
 
PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO 
ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS 
PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC AS-
SUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR 
IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS IN-
CLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR 
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY 
RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life sustaining, criti-
cal control or safety systems, or in nuclear facility applications.
It is possible that the use or implementation of any one of the concepts, applications, 
or ideas described in this document, in marketing collateral produced by or on web 
pages maintained by Dialogic may infringe one or more patents or other intellectual 
property rights owned by third parties. Dialogic does not provide any intellectual prop-
erty licenses with the sale of Dialogic products other than a license to use such prod-
uct in accordance with intellectual property owned or validly licensed by Dialogic and 
no such licenses are provided except pursuant to a signed agreement with Dialogic. 
More detailed information about such intellectual property is available from Dialogic’s 
legal department at 9800 Cavendish Blvd., Montreal, Quebec, Canada H4M 2V9. 
Dialogic encourages all users of its products to procure all necessary intellec-
tual property licenses required to implement any concepts or applications 
and does not condone or encourage any intellectual property infringement 
and disclaims any responsibility related thereto. These intellectual property 
licenses may differ from country to country and it is the responsibility of 
those who develop the concepts or applications to be aware of and comply 
with different national license requirements. 
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among others, are 
either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be 
used publicly only with permission from Dialogic. Such permission may only be 
granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, 
Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject 
to full respect of the trademark guidelines published by Dialogic from time to time and 
any use of Dialogic’s trademarks requires proper acknowledgement. The names of ac-
tual companies and products mentioned herein are the trademarks of their respective 
owners.