Configuring a Port for a Dedicated Connection
5-24
PortMaster Configuration Guide
The PortMaster supports Stac LZS data compression only for PPP connections with 
bidirectional compression. Stac LZS data compression cannot be used for SLIP 
connections.
To configure compression, use the following command:
Command> set S0|W1 compression on|stac|vj|off
Table 5-4 describes the results of using each keyword.  
Note – This command is used only on network hardwired asynchronous ports. Dial-in 
users must use the user table or RADIUS instead. Dial-out locations must use the 
location table instead.
To display compression information about a connection, enter the following command:
Command> show S0
Setting the PPP Asynchronous Map
The PPP protocol supports the replacement of nonprinting ASCII characters found in the 
datastream. These characters are not sent through the connection but are instead 
replaced by a special set of characters that the remote system interprets as the original 
Table 5-4
Keywords for Configuring Compression
Keyword
Description
on
Enables compression. The PortMaster tries to negotiate both 
Van Jacobson and Stac LZS compression on PortMaster 3 and 
on leased lines on Office Router products, or Van Jacobson 
compression only on other PortMaster products. This is the 
default.
off
Disables compression.
stac
Enables Stac LZS data compression only. Stac LZS 
compression is supported only on PortMaster 3 and leased 
lines on Office Router products.
vj
Enables Van Jacobson TCP/IP header compression only.