Configuring Dial-In Users
7-9
Configuring Network Users
The PortMaster supports Stac LZS data compression only for PPP connections with 
bidirectional compression. Stac LZS data compression cannot be used for SLIP 
connections.
To set header compression for a network user, use the following command:
Command> set user Username compression on|off
Table 7-3 describes the results of using each keyword.
To find out what type of compression was negotiated for the user, enter the following 
command:
Command> show S0
Setting Filters
Input and output packet filters can be applied to each network user. If an input filter is 
applied to a user, when the user dials in and establishes a connection, all packets 
received from the user are evaluated against the rule set for the applied filter. Only 
packets allowed by the filter can pass through the PortMaster. If an output filter is 
applied to a user, packets going to the user are evaluated against the rule set for the 
applied filter. Only packets allowed by the filter are sent out of the PortMaster to the 
user. If either filter is changed while a user is logged on, the change will not take effect 
until the user disconnects and logs in again.
Note – You must define a filter in the filter table before you can apply it. For more 
information about filters, see Chapter 9, “Configuring Filters.”
To apply an input filter for a network user, use the following command:
Command> set user Username ifilter [Filtername]
Table 7-3
Keywords for Configuring Compression
on
Enables compression. The PortMaster tries to negotiate both 
Van Jacobson and Stac LZS compression on PortMaster 3 and 
on leased lines on Office Router products, or Van Jacobson 
compression only on other PortMaster products. This is the 
default.
off
Disables compression.