Lucent Technologies PortMaster Manual Do Utilizador

Página de 364
Configuring the PortMaster 3
11-5
Configuring ISDN PRI Settings
Configuring ISDN PRI Settings 
Use the following settings to configure ISDN PRI on the PortMaster 3.
Setting the ISDN PRI Switch
The switch type information is available from your ISDN PRI service provider. To set the 
switch type for ISDN connections to the PortMaster ISDN PRI ports, use the following 
command—entered on one line
Table 11-5 explains the ISDN switch options.
Command> set isdn-switch ni-2|dms-100|4ess
|att-5ess|net5|vn2|vn3|1tr6|ntt|kdd
Setting the Framing Format
Table 11-5
ISDN Switch Options 
ISDN Switch
Description
ni-2
National ISDN-2 (NI-2) compliant. This is the default.
dms-100
Northern Telecom DMS-100 Custom.
4ess
AT&T 4ESS.
att-5ess
AT&T 5ESS.
net5
European ISDN PRI standard.
vn2
France—older switch.
vn3
France—older switch.
1tr6
Germany—older switch.
ntt
Japan.
kdd
Japan.