Lucent Technologies PortMaster Manual Do Utilizador

Página de 364
Configuration Steps for a Frame Relay Connection
13-8
PortMaster Configuration Guide
Configuring the PortMaster in Bangkok
Configure the settings for the PortMaster in Bangkok with the values in the following 
sections.
Configuring Global Settings
Configure the global settings on the PortMaster in Bangkok to the values shown in 
Table 13-1.
After you configure the global settings shown in Table 13-1, enter the following 
command to save the configuration:
Command> save all
For more information about global parameters, refer to Chapter 3, “Configuring Global 
Settings
.”
Configuring Ethernet Interface Settings
Configure the Ethernet interface settings on the PortMaster in Bangkok to the values 
shown in Table 13-2.
After you configure the Ethernet interface as shown in Table 13-2, enter the following 
command to save the configuration:
Command> save all
Table 13-1
Global Values
Parameter
Command
Gateway
set gateway 192.168.20.2
Table 13-2
Ethernet Values
Parameter
Command
IP address
set ether0 address 192.168.200.1
Netmask
set ether0 netmask 255.255.255.0