 Unit Installation
NetVanta 3200/3300/3400 Series
 68
Copyright © 2012 ADTRAN, Inc.
61200860L1-34AB
Figure 33.  Wall Mounting the NetVanta PoE Power Supply
Instructions for Wall Mounting the NetVanta PoE Power Supply
Step
Action
1
Decide on a location for the power supply. Keep in mind that the power supply needs to be mounted close 
enough to the NetVanta unit for the cords to reach the receptacles.
2
Prepare the mounting surface by attaching a board (typically plywood, 3/4-inch to 1-inch thick) to a wall 
stud using #6 to #10 (2.5-inch or greater in length) wood screws.
Important! Mounting to a stud ensures stability. Using sheetrock anchors may not provide 
sufficient long-term stability. 
3
Install two #8 PAN head screws (1-inch or greater in length) into the mounted board, following these 
guidelines and referring to 
Mark the exact positioning of the screws by using the keyhole slots on the sides of the unit as a 
template. 
Screws should be horizontally level with each other.
Leave approximately 1/4-inch of the screws protruding from the board to allow the heads of the screws 
to slide into place in the unit’s keyhole slots. 
4
Insert the screws through the keyhole slots in both sides of the unit and slide the slot securely onto the 
screws.
5
Proceed to the steps given in 
.
The NetVanta PoE power supply and the NetVanta base unit with which it is 
associated both should be installed in a restricted access location as described in 
UL 60950-1.
Under full load, the NetVanta PoE power supply may be hot to the touch.