Avaya CMC1 Manual Do Utilizador

Página de 370
Connect External Alarms and Auxiliary Connections
Issue 10 June 2005
115
 
Figure 46: 1151B2 Power Supply — Front 
Connect External Alarms and Auxiliary Connections
Note:
Note:
The AUX connector is part of the Processor Interface cable assembly (J1).
Alarm Input
Alarms can be generated on adjunct equipment, sent to the DEFINITY System, and recorded 
and reported as “external alarms.” A typical major alarm input is from a UPS.
1. Connect 1 major alarm input wire pair and 1 minor alarm input wire pair to the auxiliary field 
from the AUX connector (J1 on Processor Interface Cable). See 
.
pwr_sup1 CJL 051496
Table 19: Alarm Inputs at AUX Connector
Alarm Input 
Type
Color
AUX Connector
Major
White-Blue
AP1 (Pin 26) 
Blue-White
Ground (Pin 1)
Minor
White-Orange
AP2 (Pin 27) 
Orange-White
Ground (Pin 2)