Installing and Cabling the Cabinets
148 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
5. Set the 
Modem Connection: 
field to external if a modem is installed. Set the field to 
none if no modem is installed. This field must be administered or alarms will be generated. 
Note:
Note:
The 
Modem Connection: 
field cannot be set to none if Alarm Origination is 
activated.
6. Set the 
Data Bits:
 field to 8 (default).
7. Set the 
Parity:
 field to none (default).
8. For non-United States installations, set the remaining modem fields as shown in 
.
9. Press Enter when the modem fields are properly administered.
Table 29: Modem Fields 
Field
Description
Modem 
Connection
Default is none. Set to external if a modem is used.
Modem Name
This field is 20 characters long and permits alphanumeric 
characters to provide a unique qualifier for a given modem.
RTS/CTS 
Enabled
Informs modem that communication with the data source UART 
is driven with RTS/CTS flow control. The default 6-character 
field name is &H1. Set the field name to \Q3 for Intel modems. 
This field is not case-sensitive.
Asynchronous 
Data Mode
Configures modem as an asynchronous device. This 
8-character field name has a default value of &M0 (default). Set 
the field to &M0&Q0 for Intel modems. This field is not 
case-sensitive. 
DTE Auto-Data 
Speed
Adjusts the speed of the data source (DTE) UART to the 
outgoing (modem-to-modem) data rate. At maximum, this speed 
is 9600 baud. It is not desirable to have the serial data fill the 
modem buffer faster than the outgoing data rate, since data 
compression is disabled. The field name has a 6-character blank 
default value. The Paradyne products use S90=1 to enable this 
functionality while the Intel product uses \J1 to enable similar 
functionality. This field is not case-sensitive. 
Disable Data 
Compression
Turns off the default data compression algorithms used by most 
modems. The field has a blank field of 6 characters as default. 
The AT commands that control this are supported by similar 
commands; however, these commands do not operate in the 
same manner. The Intel modems require H0%C0 to disable 
V.42bis & MNP Class 5 data compression algorithms. The 
Paradyne products only use %C0 to disable both algorithms. 
This field is not case-sensitive.