Task Table
Issue 10 June 2005
191
 
3. Type neither
 
in the 
Alarm Origination to OSS Numbers
 field and press Enter. 
Note:
Note:
Disabling alarm origination prevents the system from generating alarms, thus 
preventing unnecessary trouble tickets. 
For some DEFINITY ECS software versions, set the 
Cleared Alarm 
Notification 
and 
Restart Notification
 fields to disable before 
pressing Enter.
Check Link Status
To check link status:
1. Enter display communication-interface links and press Enter. Write down all enabled 
links
2. Type status link number and press Enter for each enabled link.
3. Write down which links are in service.
Save Translations
To save translations:
1. Type save translation and press Enter to write all translations from memory to the original 
translation flashcard, which takes about 10 minutes.
When the save translations is successful, the error code must be a zero; otherwise, the 
translations are not copied. If the translations were corrupted, the following error message 
displays when logging in:
!
WARNING:
WARNING:
Translation corruption detected; call Avaya distributor immediately.
Note:
Note:
The save translation command cannot function if translations are corrupt. Refer 
to 
on page 358 to clear the problem.