Справочник Пользователя для Avaya CMC1
Task Table
Issue 10 June 2005
191
3. Type neither
in the
Alarm Origination to OSS Numbers
field and press Enter.
Note:
Note:
Disabling alarm origination prevents the system from generating alarms, thus
preventing unnecessary trouble tickets.
preventing unnecessary trouble tickets.
For some DEFINITY ECS software versions, set the
Cleared Alarm
Notification
and
Restart Notification
fields to disable before
pressing Enter.
Check Link Status
To check link status:
1. Enter display communication-interface links and press Enter. Write down all enabled
links
2. Type status link number and press Enter for each enabled link.
3. Write down which links are in service.
Save Translations
To save translations:
1. Type save translation and press Enter to write all translations from memory to the original
translation flashcard, which takes about 10 minutes.
When the save translations is successful, the error code must be a zero; otherwise, the
translations are not copied. If the translations were corrupted, the following error message
displays when logging in:
translations are not copied. If the translations were corrupted, the following error message
displays when logging in:
!
WARNING:
WARNING:
Translation corruption detected; call Avaya distributor immediately.
Note:
Note:
The save translation command cannot function if translations are corrupt. Refer
to
to
on page 358 to clear the problem.