Avaya X330WAN Manual Do Utilizador

Página de 264
DTE X.21
Avaya X330WAN User’s Guide
225
DTE X.21
Introduction
Figure A.2 shows the Avaya serial to X.21 cable and Table A.2 shows the pinouts. 
The arrows indicate the signal direction – --> means DTE to DCE and <-- means 
DCE to DTE.
Figure A.2
Avaya™ serial cable DTE X.21 Cable
Pinouts
Table A.2
X.21 DCE Serial Cable Pinouts
 Serial 
connector pin
Signal name
Note
Direction
DB-15 
connector 
pin
Drain wire
Shield GND
P2-1
P1-1
P1-14
TXD+
TXD-
Twisted pair #5
-->
-->
P2-2
P2-9
P1-8
P1-9
RTS+
RTS-
Twisted pair #3
-->
-->
P2-3
P2-10
P1-5
P1-18
RXD+
RXD--
Twisted pair #8
<--
<--
P2-4
P2-11
P1-11
P1-10
CTS+
CTS-
Twisted pair #2
<--
<--
P2-5
P2-12
P1-4
P1-17
RXC+
RXC-
Twisted pair #7
<--
<--
P2-6
P2-13
Not connected
P2-14
P2-15
P2-7
P1-22
P1-23
Not connected
8
15
1
9
P1
P2
Avaya™  serial cable DTE X.21
26
13
14
1
CB0314