Filter prevents dust from accumulating on the optical elements inside the projector. Should the filter becomes 
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup 
and adversely affect the life of the projector. This projector has an electrically operated filter which helps you 
to replace the filter easily. The projector monitors the condition of the filter at all time and replaces a filter with 
a new one automatically when it detects the clogging. 
If the projector reaches a time set in the timer setting 
(p.65), a Filter replacement icon (Fig.1) appears on the 
screen and the WARNING FILTER indicator on the top 
panel lights up (p.81). When you see this icon, replace 
the filter as soon as possible (pp.30, 58). If the filter is out 
of scroll and the projector reaches a time set in the timer 
setting, Fig. 2 appears on the screen, indicating that the 
filter cartridge replacement is necessary.
When the filter scroll is counted down to 
0, the Last scroll 
icon (Fig.3) appears on the screen, indicating that there is 
one scroll left in the filter cartridge (p.65).
If the projector detects that the filter is clogged and 
no scroll is left in the filter cartridge, a Filter cartridge 
replacement icon (Fig. 4) appears on the screen and the 
WARNING FILTER indicator on the top panel lights up 
(p.81). When you see this icon, replace the filter cartridge 
(p.67) and reset the Filter counter (p.68) and the Scroll 
counter (p.68).
When the filter is being scrolled using the remote control 
(p.30) or the Filter control function in the setting menu 
(p.58), a Filter replacement icon and
 Please wait . . . 
message (Fig.5) appear on the screen and the WARNING 
FILTER indicator blinks slow (approx. 2 seconds ON, 2 
seconds OFF) (p.79).
The WARNING FILTER indicator blinks fast when the 
projector detects an abnormal condition, the filter cartridge 
is not installed properly, or the filter scroll is not working 
properly (p.81).
Fig .1   Filter replacement icon
Fig .4   Filter cartridge replacement icon
Fig .3   Last scroll icon
Maintenance and Care
Note:
  • Fig.1, Fig.2, Fig.3, Fig. 4 and Fig.5 will not appear
when the Display function is set to
Off (p.52) or during
“Freeze” (p.30).
 • The filter cannot be rewound.
 • The filter can be scrolled 9 times since in the filter
cartridge there are 10 scrolls in total.
 • The filter cartridge is disposable. Do not clean and
reuse the filter cartridge.
 • Do not expose the filter cartridge to water or liquid, or it
may cause a breakdown.
 • Replace the filter cartridge after all the scrolls are used
up. If you replace the filter cartridge when there are
some scrolls left in the filter cartridge, the filter counter
and the scroll counter do not recognize the correct
number of remaining scrolls and the reset function
cannot work properly. It may cause a breakdown.
 • Do not use the filter cartridge with other projector.
Fig .5   Filter replacement icon and 
Please wait . . . message. 
The filter counter and the scroll counter
do not recognize the correct number
of remaining scrolls of the used filter
cartridge and the reset function cannot
work properly. It may cause a breakdown.
 • Make sure that the projection lamp is
turn off when you are replacing the filter
cartridge. If you replace the filter cartridge
when the projection lamp is turn on, the
projector will be shut down automatically
for safety purpose.
 • Do not forget to reset the filter counter
and the scroll counter in the setting
menu after replacing the filter cartridge.
If you forget to reset the filter counter
and the scroll counter, the projector
cannot recognize the correct number
of remaining scrolls and may cause a
breakdown.
 • When the projector is kept being used
for 3 minutes without getting the filter
cartridge replaced after the Fig.4 appears
on the screen, the projector is turned off
automatically to prevent the damage of
optical components.