Selecting the Line
89
3
Selecting the Line
This feature requires the optional Extra G3 Interface Unit or the optional ISDN Unit.
Installing all of these options expands
the machine's line capacity to a maxi-
mum of 3 lines.
The optional Extra G3 Interface Unit
connects to the PSTN, the optional
ISDN Unit to the ISDN.
Note
❒ Only one PSTN line is available
with the base machine without any
options installed.
❒ Up to three lines can be used si-
multaneously.
❒ One ISDN line allows you to com-
municate with two communica-
tion lines, however, if connected
through PBX, you may only be
able to use one communication
line.
❒ The optional Extra G3 Interface
Unit can be connected to a PSTN
line.
❒ The optional Extra G3 Interface
Unit can be for reception exclusive
use. To change the setups, please
contact your service representa-
tive.
❒ The optional ISDN Unit can be
connected to an ISDN line.
❒ When sending a fax and choosing
the line, you can only specify desti-
nations with the number keys and
the Chain Dial feature.
❒ The following display is shown
when neither the optional Extra G3
Interface Unit or optional ISDN
Unit is installed.
❒ You can set the default G3 line or
expanded G3 line as the PABX line
with User Parameters. See p.178
“User Parameters” (s
witch 13 bit
0), (switch 13 bit 2).
❒ The On Hook Dial function is not
available with the lines expanded
by the optional units. See p.85 “On
Hook Dial”
.
❒ Your machine may not respond to
a transmission received through
an ISDN PBX, detecting it as a tele-
phone call, not as a fax message.
You can set "Respond to a trans-
mission received through an ISDN
PBX unconditionally" to "On" with
User Parameters. See p.178 “User
Parameters”
 (switch 13 bit 6).
❒ The table for the available combi-
nation of the connected line type(s)
and the communication type(s) is
as follows:
Option 
Compo-
nent(s)
Connected 
Line 
Type(s)
Available 
Communi-
cation 
Type(s)
Base 
Machine
PSTN G3
Base Ma-
chine + Op-
tional Extra 
G3 Interface 
Unit
PSTN + 
PSTN 
(Option)
G3 + G3
Base Ma-
chine + Op-
tional ISDN 
Unit
PSTN + 
ISDN 
(Option)
G3 + G4
I-G3 + G4
G3 + G4 + 
G4
G4 + G4
ISDN 
(Option)
I-G3 + G4
G4 + G4