  Troubleshooting Procedures  
   
2-16 [CONFIDENTIAL] TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813) 
Check 1  Convert the DC IN icon blink pattern into the hexadecimal error code and compare 
it to the tables below. Then go to Check 2. 
Table 2-3  Error code 
Error code 
Where error occurs 
1*h 
DC Power (AC Adapter) 
2*h Main 
battery 
3:h 2nd 
battery 
4*h 
S3V output  
5*h E5V 
output 
6*h 
E3V output  
7*h IGD-PGV 
output 
8*h 
1R5-B1V output  
9*h PPV 
output 
A*h 1R05-E1V 
output 
B*h IGD-PGV 
output 
C*h PTV 
output 
D*h PTV 
output 
E*h - 
F*h - 
 
  DC power supply (AC adapter) 
Error code  Meaning 
10h 
AC Adapter output voltage is over 16.5V. 
11h 
Common Dock output voltage is over 16.5V.. 
12h 
Current from the DC power supply is over 4.95A. 
13h 
Current from the DC power supply is over 0.5A when there is no load. 
14h 
The compensation value of [0A] is not within the limits from design data (± 
481mA).