  Troubleshooting Procedures  
   
2-18 [CONFIDENTIAL] TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813) 
  E3V output  
Error code  Meaning 
60h 
E3V voltage is over 3.96V. 
61h 
E3V voltage is under 2.81V when the computer is powered on. 
62h 
E3V voltage is under 2.81V when the computer is booting up. 
64h 
E3V voltage is under 2.81V when EV power is maintained. 
 
  IGD-PGV output 
Error code  Meaning 
70h 
IGD-PGV voltage is over 1.80V. 
71h 
IGD-PGV voltage is under 0V when the computer is powered on. 
72h 
IGD-PGV voltage is under 0V when the computer is booting up. 
 
  1R5-P1V output 
Error code  Meaning 
80h 
1R5-P1V voltage is over 1.80V. 
81h 
1R5-P1V voltage is under 1.28V when the computer is powered on. 
82h 
1R5-P1V voltage is under 1.28V when the computer is booting up. 
84h 
1R5-P1V voltage is under 1.28V when BV power is maintained. 
 
  PPV output 
Error code  Meaning 
90h 
PPV voltage is over 1.68V. 
91h 
PPV voltage is under 0.00V when the computer is powered on. 
92h 
PPV voltage is under 0.55V when the computer is booting up.