Toshiba S500M Manual Do Utilizador

Página de 477
   
  Troubleshooting Procedures  
TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813) [CONFIDENTIAL] 
2-19 
  1R05-E1V output  
Error code 
Meaning 
A0h 
1R05-E1V voltage is over 1.26V. 
A1h 
1R05-E1V voltage is under 0.89V when the computer is powered on. 
A2h 
1R05-E1V voltage is under 0.89V when the computer is booting up. 
A4h 
1R05-E1V voltage is under 1.26V when EV power is maintained. 
 
  IGD-PGV output 
Error code 
Meaning 
B0h 
PTV voltage is over 1.80V. 
B1h 
PTV voltage is under 0V when the computer is powered on. 
B2h 
PTV voltage is under 0V when the computer is booting up. 
 
  PTV output 
Error code 
Meaning 
C0h 
IGD-PGV voltage is over 1.26V. 
C1h 
IGD-PGV voltage is under 0.67V when the computer is powered on. 
C2h 
IGD-PGV voltage is under 0.67V when the computer is booting up. 
 
  PTV output 
Error code 
Meaning 
D0h 
SPURS-PPV voltage is over 1.26V. 
D1h 
SPURS-PPV voltage is under 0.89V when the computer is powered on. 
D2h 
SPURS-PPV voltage is under 0.89V when the computer is booting up. 
 
  Miscellaneous   
Error code 
Meaning 
F0h 
The sub clock does not oscillate.