Toshiba 960-809 Manual Do Utilizador

Página de 484
Tests and Diagnostics 
 
3-16 
 [CONFIDENTIAL]  
PORTEGE M780 Maintenance Manual (960-809) 
7.  “Create DMIINFO TXT (Y/N)?” is displayed. Press Y, then the 
DMI information (text data) is written to the Floppy disk, etc. 
Setting of the HWSC 
Setting of the UUID 
Display of the DMI information (including UUID) 
After completion of the above settings, H/W configuration & DMI 
information are appeared in order. Check the contents and press Enter
Subtest 02 
DMI information save 
NOTE:  Before replacing the system board, be sure to execute this subtest and save the 
DMI information to the floppy disk. 
This is one of tools to copy the DMI information to a new PCB after 
replacing.  
This subtest saves all the DMI data in a floppy disk.  
Subtest 03 
DMI information recovery 
This is one of tools to copy the DMI information to a new PCB after 
replacing.  
This subtest writes all the DMI data in the floppy disk into the new PCB.  
NOTE:  Since the data of UUID is updated every time when this subtest, DMI information 
recovery, is done, the saved UUID data is not written.