3.6 Memory Test 
3  Diagnostic Programs 
Pattern Size: Choose the pattern size – BYTE, WORD, DWORD or ALL. 
Percent (%): Choose the percentage of the defined range of the memory to 
be tested. 
Time Limit(h): Choose or Input the time (hour) of the defined range of the 
memory to be tested. 
Time Limit(m): Choose or Input the time (minute) of the defined range of 
the memory to be tested. 
Subtest 03 Patterns 
This test item is to check whether the system memory includes base memory and 
extended memory that could be accessed correctly through writing and reading 
with a series of designed pattern data. Below is the parameter setting dialog 
window. 
 
Test Option: Choose the Memory part to take the test– Base Memory or 
Extended Memory. 
Extended Memory Test Range: Specify the test coverage range of 
Extended Memory. If user chooses Total Size, it means that the whole 
Extended Memory will be tested. Although user can input the parameter 
into other select box, but the selected result is invalid. If user chooses 
Special Size, the test of Extended Memory will be taken according to the 
coverage range that user chooses or time. 
Extended Memory Start Address (MB) & Extended Memory End 
Address (MB): 
Set the range of extended memory that is to be tested, the 
test coverage would be based on the setting and the value in ‘Percent (%) 
mentioned at below. 