Cabletron Systems SEHI-22FL Guia Do Utilizador

Página de 85
SEHI User’s Guide
A-1
APPENDIX A
EPIM INFORMATION
A.1
EPIM SPECIFICATIONS
EPIMs enable the connection of the SEHI to the main network using 
different media types. Cabletron Systems offers a variety of EPIMs. The 
following sections explain specifications for each EPIM.
A.1.1
EPIM-T
The EPIM-T is an RJ45 connector supporting UTP cabling. It has an 
internal Cabletron Systems TPT-T 10BASE-T Twisted Pair Transceiver.
The slide switch on the EPIM-T determines the crossover status of the 
cable pairs. If the switch is on the 
X
 side, the pairs are internally crossed 
over. If the switch is on the 
=
 side, the pairs are not internally crossed 
over. Figure A-1 shows the pinouts for the EPIM-T in both positions.
Figure A-1
EPIM-T Pinouts
Position =
(not crossed over)
1. TX+
2. TX-
3. RX+
4. NC
5. NC
6. RX
7. NC
8. NC
Position X
(crossed over)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
8. NC
1490_29
SEHI Book  Page 1  Friday, April 19, 1996  10:46 AM