Cabletron Systems SEHI-22FL Guia Do Utilizador

Página de 85
Appendix A: EPIM Information
A-2
SEHI User’s Guide
A.1.2
EPIM-F1 and EPIM-F2 
The EPIM-F1 and EPIM-F2 shown in Figure A-2 support Multimode 
Fiber Optic cabling. Each EPIM has an internal Cabletron Systems
FOT-F Fiber Optic Transceiver. The EPIM-F1 is equipped with SMA 
Connectors and the EPIM-F2 is equipped with ST Connectors. 
Specifications for the EPIMs are listed below.
Figure A-2
EPIM-F1 and EPIM-F2
The transmitter power levels and receive sensitivity levels listed are Peak 
Power Levels after optical overshoot. Use a Peak Power Meter to compare 
the values given above to those measured on any particular port. If Power 
Levels are being measured with an Average Power Meter, add 3 dBm to 
the measurement to compare the measured values to the values listed (i.e. 
-33.5 dBm average + 3 dBm =-30.5 dBm peak).
Parameter
Typical
 
Value
Worst
Case
Worst 
Case 
Budget 
Typical 
Budget
Receive
Sensitivity
-30.5 dBm
-28.0 dBm
   
Peak Input Power
-7.6 dBm
-8.2 dBm
Transmitter Power 
50/125 
µ
m fiber
-13.0 dBm
-15.0 dBm
13.0 dB
17.5 dB
62.5/125 
µ
m fiber
-10.0 dBm
-12.0 dBm
16.0 dB
20.5 dB
100/140 
µ
m fiber
-7.0 dBm
-9.0 dBm
19.0 dB
23.5 dB
Error Rate
Better than 10
-10
1490_30
1490_31
SEHI Book  Page 2  Friday, April 19, 1996  10:46 AM