Multi-drop 4-Wire, Full Duplex Communications: 
In a multi-drop 4-wire differntial network, two to 32 devices are connected together. Note that 
each RS-485 receiver counts as a device or “load”. In this multi-drop mode of communication, a 
master slave protocol must be enforced, that is, all communication is initiated by the master, in 
this case a Blue Heat/Net Sync. The communication is “full duplex”, meaning that receive and 
transmit traffic occur on different pairs of wires. The Blue Heat/Net Sync can receive and 
transmit data from/to a device at the same time. 
 
Basic - Wire, Half Duplex Multi-drop Connection: 
In a 2-wire differntial network, two to 32 devices are connected together. Note that each receiver 
counts as a device or “load”. In this multi-drop mode of communication a master slave protocol 
must be enforced, that is, all communication is initiated by the master, in this case a Blue 
Heat/Net Sync. The communication is “half duplex”, meaning that receive and transmit traffic 
occur on the same wire. The Blue Heat/Net Sync and devices can not receive data and transmit 
data at the same time.  
 
Note that the Receiver +/- and the Transmitter +/- signals are connected together. This is 
performed at the DB-9 connectors. All communication between devices occurs over a single pair 
of wires; this can lower the cost of wiring your network.