Bus Contention on Differential Multi-drop Networks:  
 
Bus contention occurs when two or more devices enabled on a bus attempt to run the bus to 
opposite logic values. From the diagram above, we can see that there are multiple differential 
transmitters (TXD) on the bus. To avoid the bus contention problem, the differential transmitter 
features a tri-state, or high impedance mode controlled by an input pin (enable). Software and 
hardware in the Blue Heat/Net Sync and the differential devices will always place its transmitter 
into the high impedance mode when not transmitting.  This feature is managed by the Blue 
Heat/Net Sync and is fully transparent to your application. 
 
For example, in a multi-drop network, the differential transmitter is enabled prior to the master 
initiating transmission. When transmission is complete, the transmitter is placed in high 
impedance mode. Each slave will receive that transmission from the master. (A protocol must be 
in place to address, or select, the desired slave device, but that discussion is beyond the 
intentions of this tutorial, and is entirely application dependent). When the slave device has 
received the data, it will respond by enabling its transmitter and transmitting data onto the bus, 
then placing its transmitter into high impedance mode, just as the master did.